Terahertz FMCW inspection of GFRP composites: Comparison with Conventional NDT Techniques and Enhanced Defect Detection Capability through Semi-automatic 3-D Image Processing

C. Matheis, S. Wohnsiedler, F. Ospald, E. Cristofani, A. Brook, J. Jonuscheit, R. Beigang, M. Vandewal

Onderzoeksoutput: Hoofdstuk in Boek/Rapport/CongresprocedureConferentiebijdragepeer review

Samenvatting

A range of composite materials that contain glass fiber reinforced polymers is inspected for various defects such as debonds, delaminations and foreign inclusions with a terahertz FMCW imaging system. The results are evaluated manually and by means of semi-automatic image processing, which enhances the detection rate. Comparison with reference measurements from established NDT techniques shows high defect detectability with the terahertz approach.

Originele taal-2Engels
Titel8th German Microwave Conference, GeMiC 2014
UitgeverijVDE Verlag GmbH
ISBN van elektronische versie9783800735853
StatusGepubliceerd - 2019
Evenement8th German Microwave Conference, GeMiC 2014 - Aachen, Duitsland
Duur: 10 mrt. 201412 mrt. 2014

Publicatie series

Naam8th German Microwave Conference, GeMiC 2014

Congres

Congres8th German Microwave Conference, GeMiC 2014
Land/RegioDuitsland
StadAachen
Periode10/03/1412/03/14

Vingerafdruk

Duik in de onderzoeksthema's van 'Terahertz FMCW inspection of GFRP composites: Comparison with Conventional NDT Techniques and Enhanced Defect Detection Capability through Semi-automatic 3-D Image Processing'. Samen vormen ze een unieke vingerafdruk.

Citeer dit