Doorgaan naar hoofdnavigatie Doorgaan naar zoeken Ga verder naar hoofdinhoud

Limiter biasing experiments in TEXTOR-94

  • T. Loarer
  • , J. Gunn
  • , J. L. Lachambre
  • , E. Gravier
  • , C. Boucher
  • , K. H. Finken
  • , M. Lehnen
  • , G. Mank
  • , S. Jachmich
  • , H. Van Goubergen
  • , G. Van Oost
  • Commissariat à l'Énergie Atomique et aux Énergies Alternatives
  • INRS-Energie et Matériaux
  • Max Planck Institute for Plasma Physics
  • University of Ghent

Onderzoeksoutput: Bijdrage aan een tijdschriftArtikelpeer review

3 Citaten (Scopus)

Samenvatting

Particle collection by the ALT-II belt limiter in the TEXTOR-94 tokamak is exclusively limited to the parallel outflux because the scoop walls that are oriented parallel to the field lines obstruct the poloidal ExB mass flow. With normal Btor direction (ExB towards the scoops), a threefold decrease of plenum pressure is measured during negative biasing, while with reversed Btor (ExB away from the scoops), a 60% pressure increase is observed. This behaviour is exactly opposite to that observed in X-point divertors. A simple fluid model explains this apparent contradiction, and gives good quantitative agreement with measurements of the parallel Mach number in the SOL. The essential physics is governed by the Bohm-Chodura criterion.

Originele taal-2Engels
Pagina's (van-tot)1021-1031
Aantal pagina's11
TijdschriftCzechoslovak Journal of Physics
Volume51
Nummer van het tijdschrift10
DOI's
StatusGepubliceerd - okt 2001

Vingerafdruk

Duik in de onderzoeksthema's van 'Limiter biasing experiments in TEXTOR-94'. Samen vormen ze een unieke vingerafdruk.

Citeer dit