Attenuation measurement of an atomic hydrogen beam as a diagnostic technique to determine the light impurity content of a plasma

  • M. C. Hublet
  • , G. Van Wassenhove
  • , E. Desoppere
  • , M. Jadoul
  • , G. Van Oost
  • Royal Military Academy of Belgium

Onderzoeksoutput: Bijdrage aan een tijdschrift › Artikel › peer review

2 Citaten (Scopus)

Samenvatting

The attenuation of a low intensity atomic hydrogen or deuterium beam, injected into the plasma of the ERASMUS Tokamak, was investigated during the whole duration of the discharge, as a function of the beam energy (3-15 keV) and of the radial position of the injection chord. The comparison with attenuations calculated from impurity models adapted to the ERASMUS plasma allows the evaluation of the content of oxygen assuming that this is the only light impurity. The sensitivity of the diagnostic was tested by injection of test impurities, such as oxygen and helium, and during RF heating in the ion-cyclotron range of frequencies.

Originele taal-2Engels
Artikelnummer002
Pagina's (van-tot)829-842
Aantal pagina's14
TijdschriftPlasma Physics and Controlled Fusion
Volume30
Nummer van het tijdschrift7
DOI's
StatusGepubliceerd - 1988