Doorgaan naar hoofdnavigatie Doorgaan naar zoeken Ga verder naar hoofdinhoud

Analysis of metallic impurity content by means of VUV and SXR diagnostics in hybrid discharges with hot-spots on the JET-ITER-like wall poloidal limiter

  • JET Contributors
  • Institute of Plasma Physics and Laser Microfusion
  • Culham Centre for Fusion Energy
  • Max Planck Institute for Plasma Physics
  • ENEA Centro Ricerche Frascati
  • École Polytechnique Fédérale de Lausanne
  • ICREA
  • Barcelona Supercomputing Center
  • Instituto Superior Técnico
  • University of Opole
  • Consorzio Rfx

Onderzoeksoutput: Bijdrage aan een tijdschriftArtikelpeer review

10 Citaten (Scopus)

Samenvatting

In preparation for the upcoming JET D-T campaign, great effort has been devoted during the 2015-2016 JET campaigns with the ITER-like wall (ILW) to the extension of the high performance H-mode phase in baseline and hybrid scenarios. Hybrid discharges were the only ones that have been stopped by the real-time vessel protection system due hot-spot formation on the outboard poloidal limiter. Generation of hot-spots was linked to the application of high neutral beams injection and ion cyclotron resonance heating (ICRH) power. In tokamaks with high-Z plasma components, the use of ICRH heating is also accompanied by an increased metallic impurity content. Simultaneous control of hot-spot temperature and the core impurity content was crucial due to the fact that the same plasma-wall interaction mechanism is responsible for both phenomena. Impurity data collected by SXR, EUV and VUV diagnostics were able to provide for the first time comprehensive information concerning tungsten and mid-Z impurities such as nickel, iron, and cooper. To determine absolute mid-Z impurity concentrations a new relative calibration technique, compatible with JET-ILW, has been developed based on cross-calibration with a calibrated spectrometer via the quasicontinuum of W in the 200-400 Å wavelength range. In hybrid discharges, it was found that local D2 gas injection, plasma current, separatrix density, and fast ion losses appeared to impact hot-spot temperature and core impurity levels. Analysis showed a reduced maximum hot-spot temperature and impurity concentration at higher gas rate. Changes in the plasma current had a strong impact on the plasma-wall interaction, both via modifications in the edge density and in the fast ion losses. At constant gas injection rate, both the hot-spot temperature and the core impurity content decreased with the separatrix density. The main mechanism responsible for the formation of the hot-spots was found to be linked to the fast ion losses, but RF sheath effects may also be playing a role in the high limiter temperatures observed in these experiments.

Originele taal-2Engels
Artikelnummer085004
TijdschriftPlasma Physics and Controlled Fusion
Volume61
Nummer van het tijdschrift8
DOI's
StatusGepubliceerd - 21 jun. 2019

Vingerafdruk

Duik in de onderzoeksthema's van 'Analysis of metallic impurity content by means of VUV and SXR diagnostics in hybrid discharges with hot-spots on the JET-ITER-like wall poloidal limiter'. Samen vormen ze een unieke vingerafdruk.

Citeer dit