Résumé
A scaled mock-up (1/4) of the proposed W7-X ICRF antenna has been constructed and placed in front of dielectric dummy loads. It allows comparing measured and predicted coupling performances and hence validating the electrical design of the antenna. High dielectric constant materials are needed for the dummy load to mimic the plasma. Salted water and a mix of the ferroelectric BaTiO3 and salted water are used. The measurements are compared with the expectations of 3 codes: ANTITER II, MWS and TOPICA. The best agreement is obtained with the BaTiO3 load for all phasings.
| langue originale | Anglais |
|---|---|
| Pages (de - à) | 463-467 |
| Nombre de pages | 5 |
| journal | Fusion Engineering and Design |
| Volume | 96-97 |
| Les DOIs | |
| état | Publié - 1 oct. 2015 |
Empreinte digitale
Examiner les sujets de recherche de « Validation of the electrical design of the W7-X ICRF antenna on a reduced-scale mock-up ». Ensemble, ils forment une empreinte digitale unique.Contient cette citation