Timing and source of the maximum of the transthoracic impedance cardiogram (dZ/dt) in relation to the H-I-J complex of the longitudinal ballistocardiogram under gravity and microgravity conditions

E. Luchitskaya, Q. Deliere, A. Diedrich, N. Pattyn, A. Almorad, L. Beck, P. Gauger, U. Limper, I. Funtova, R. M. Baevsky, P. F. Migeotte, J. Tank

Résultats de recherche: Chapitre dans un livre, un rapport, des actes de conférencesContribution à une conférenceRevue par des pairs

Résumé

The transthoracic impedance cardiogram (ICG) and the acceleration ballistocardiogram (BCG) measured close to the center of mass of the human body are generated by changes of blood distribution. The transthoracic ICG is an integrated signal covering the whole thorax and spatial resolution is poor. Comparison between both signals can be used to elucidate the source of the ICG signal. We recorded the ECG, ICG, and BCG simultaneously in healthy subjects under resting and microgravity conditions during parabolic flights. The time interval between the R-peak of the ECG and the maximum of the ICG (R-dZ/dtmax) and the time interval between the R-peak of the ECG and the I-peak in the BCG (R-I) differed significantly (p<0.0001). The I-peak in the BCG always occurred earlier during systole than dZ/dtmax. The delay of dZ/dtmax ranged between 23 and 28 ms at rest and was lowest under microgravity conditions (12±4 ms, p<0.02). Our results suggest that both signals have different sources. Combination of modern imaging techniques with classical non invasive approaches to detect changes of blood distribution may provide new insights into the complex interaction between blood flow and mechanocardiographic signals like the BCG.

langue originaleAnglais
titre2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013
EditeurInstitute of Electrical and Electronics Engineers Inc.
Pages7294-7297
Nombre de pages4
ISBN (imprimé)9781457702167
Les DOIs
étatPublié - 2013
Evénement2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013 - Osaka, Japon
Durée: 3 juil. 20137 juil. 2013

Série de publications

NomProceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
ISSN (imprimé)1557-170X

Une conférence

Une conférence2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013
Pays/TerritoireJapon
La villeOsaka
période3/07/137/07/13

Empreinte digitale

Examiner les sujets de recherche de « Timing and source of the maximum of the transthoracic impedance cardiogram (dZ/dt) in relation to the H-I-J complex of the longitudinal ballistocardiogram under gravity and microgravity conditions ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation