Résumé
This paper describes the design, implementation and operation of the near infrared (NIR) imaging diagnostic system of the JET ITER-like wall (JET-ILW) plasma experiment and its integration into the existing JET protection architecture. The imaging system comprises four wide-angle views, four tangential divertor views, and two top views of the divertor covering 66% of the first wall and up to 43% of the divertor. The operation temperature ranges which must be observed by the NIR protection cameras are, for the materials used on JET: Be 700 °C-1400 °C; W coating 700 °C-1370 °C; W bulk 700 °C-1400 °C. The Real-Time Protection system operates routinely since 2011 and successfully demonstrated its capability to avoid the overheating of the main chamber beryllium wall as well as of the divertor W and W-coated carbon fibre composite (CFC) tiles. During this period, less than 0.5% of the terminated discharges were aborted by a malfunction of the system. About 2%-3% of the discharges were terminated due to the detection of actual hot spots.
| langue originale | Anglais |
|---|---|
| Numéro d'article | 014027 |
| journal | Physica Scripta |
| Volume | 2017 |
| Numéro de publication | T170 |
| Les DOIs | |
| état | Publié - 1 déc. 2017 |
| Evénement | 16th International Conference on Plasma-Facing Materials and Components for Fusion Applications, PFMC 2017 - Neuss/Dusseldorf, Allemagne Durée: 16 mai 2017 → 19 mai 2017 |
Empreinte digitale
Examiner les sujets de recherche de « The near infrared imaging system for the real-time protection of the JET ITER-like wall ». Ensemble, ils forment une empreinte digitale unique.Contient cette citation