Passer à la navigation principale Passer à la recherche Passer au contenu principal

Sensitive and specific recombinase polymerase amplification assays for fast screening, detection, and identification of Bacillus anthracis in a field setting

  • Mostafa Bentahir
  • , Jérôme Ambroise
  • , Cathy Delcorps
  • , Paola Pilo
  • , Jean Luc Gala
  • Université Catholique de Louvain
  • ACOS O&T/DLD
  • University of Bern

Résultats de recherche: Contribution à un journalArticleRevue par des pairs

26 Citations (Scopus)

Résumé

Four isothermal recombinase polymerase amplification (RPA) assays were developed for fast in-field identification of Bacillus anthracis. The RPA assays targeted three specific sequences (i.e., the BA_5345 chromosomal marker, the lethal factor lef [from pXO1], and the capsule-biosynthesis-related capA [from pXO2]) and a conserved sequence in the adenylate cyclase gene (adk) for the Bacillus cereus group. B. anthracis-specific RPA assays were tested first with purified genomic DNAs (n = 60), including 11 representatives of B. anthracis, and then with soil (n = 8) and white powder (n = 8) samples spiked with inactivated B. anthracis spores and/or other biological agents. The RPA assays were also tested in another laboratory facility, which blindly provided DNA and lysate samples (n = 30, including 20 B. anthracis strains). RPA assays displayed 100% specificity and sensitivity. The hands-off turnaround times at 42°C ranged from 5 to 6 min for 102 genomic copies. The analytical sensitivity of each RPA assay was ~10 molecules per reaction. In addition, the BA_5345 and adk RPA assays were assessed under field conditions with a series of surface swabs (n = 13, including 11 swabs contaminated with B. thuringiensis spores) that were blindly brought to the field laboratory by a chemical, biological, radiological, and nuclear (CBRN) sampling team. None of the 13 samples, except the control, tested positive for B. anthracis, and all samples that had been harvested from sporecontaminated surfaces tested positive with the adk RPA assay. All three B. anthracisspecific RPA assays proved suitable for rapid and reliable identification of B. anthracis and therefore could easily be used by first responders under field conditions to quickly discriminate between a deliberate release of B. anthracis spores and a hoax attack involving white powder.

langue originaleAnglais
Numéro d'articlee00506-18
journalApplied and Environmental Microbiology
Volume84
Numéro de publication11
Les DOIs
étatPublié - 1 juin 2018

Empreinte digitale

Examiner les sujets de recherche de « Sensitive and specific recombinase polymerase amplification assays for fast screening, detection, and identification of Bacillus anthracis in a field setting ». Ensemble, ils forment une empreinte digitale unique.

Contient cette citation