Physiology of repeated mixed gas 100-m wreck dives using a closed-circuit rebreather: a field bubble study

Costantino Balestra, François Guerrero, Sigrid Theunissen, Peter Germonpré, Pierre Lafère

    Résultats de recherche: Contribution à un journalArticleRevue par des pairs

    Résumé

    Purpose: Data regarding decompression stress after deep closed-circuit rebreather (CCR) dives are scarce. This study aimed to monitor technical divers during a wreck diving expedition and provide an insight in venous gas emboli (VGE) dynamics. Methods: Diving practices of ten technical divers were observed. They performed a series of three consecutive daily dives around 100 m. VGE counts were measured 30 and 60 min after surfacing by both cardiac echography and subclavian Doppler graded according to categorical scores (Eftedal–Brubakk and Spencer scale, respectively) that were converted to simplified bubble grading system (BGS) for the purpose of analysis. Total body weight and fluids shift using bioimpedancemetry were also collected pre- and post-dive. Results: Depth-time profiles of the 30 recorded man-dives were 97.3 ± 26.4 msw [range: 54–136] with a runtime of 160 ± 65 min [range: 59–270]. No clinical decompression sickness (DCS) was detected. The echographic frame-based bubble count par cardiac cycle was 14 ± 13 at 30 min and 13 ± 13 at 60 min. There is no statistical difference neither between dives, nor between time of measurements (P = 0.07). However, regardless of the level of conservatism used, a high incidence of high-grade VGE was detected. Doppler recordings with the O’dive were highly correlated with echographic recordings (Spearman r of 0.81, P = 0.008). Conclusion: Although preliminary, the present observation related to real CCR deep dives questions the precedence of decompression algorithm over individual risk factors and pleads for an individual approach of decompression.

    langue originaleAnglais
    Pages (de - à)515-522
    Nombre de pages8
    journalEuropean Journal of Applied Physiology
    Volume122
    Numéro de publication2
    Les DOIs
    étatPublié - févr. 2022

    Empreinte digitale

    Examiner les sujets de recherche de « Physiology of repeated mixed gas 100-m wreck dives using a closed-circuit rebreather: a field bubble study ». Ensemble, ils forment une empreinte digitale unique.

    Contient cette citation