Passer à la navigation principale Passer à la recherche Passer au contenu principal

Electron density and temperature measurements in TEXTOR ion cyclotron wall conditioning plasmas by thermal Li beam spectroscopy

  • R. Laengner
  • , B. Unterberg
  • , A. Lyssoivan
  • , M. Paul
  • , V. Philipps
  • , A. Pospieszczyk
  • , U. Samm
  • , O. Schmitz
  • , B. Schweer
  • , G. Sergienko
  • , M. Vervier
  • Institut für Energie und Klimaforschung

Résultats de recherche: Contribution à un journalArticleRevue par des pairs

1 Citation (Scopus)

Résumé

In this contribution, we report on the application of Li beam emission spectroscopy to determine electron density and temperature in ion cyclotron wall conditioning plasmas with the help of a collisional-radiative model. Intensity ratios of atomic line emission at 670 nm, 610 nm and 460 nm have been chosen. The overall range of ne and Te in ICWC plasmas measured with the Li beam is 1016 m-3 to a few 1017 m-3 for the electron density and 1.5-15 eV for the electron temperature. With the application of oscillating vertical and horizontal magnetic fields in the range of 0.01 T the plasma extends towards the bottom of the TEXTOR vessel, providing a wider distribution of particle fluxes to the vessel walls.

langue originaleAnglais
Pages (de - à)S1166-S1169
journalJournal of Nuclear Materials
Volume415
Numéro de publication1 SUPPL
Les DOIs
étatPublié - 1 août 2011