TY - GEN
T1 - Complete space - Time validation of a single mode stirrer reverberation chamber for immunity testing
AU - Piette, Marc
PY - 2006
Y1 - 2006
N2 - This paper gives an overview of the validation measurements in a small cubic reverberation chamber (15 m3) equiped with a single mode stirrer and two TEM horns set in cross-polarization in order to enhance the unpolarized character of the stochastic fields. Frequencies of interest are between 900 MHz and 2,5 GHz. The set of results points out that what could be firstly seen as a drawback - the cubic shape - can be effectively overcome by the design quality of the stirrer. Space homogeneity, quality factor, chamber gain, stirring ratio and CDF at 900MHz and 1800MHz (GSM, DECT and DCS mobile radio systems) are presented and critically commented.
AB - This paper gives an overview of the validation measurements in a small cubic reverberation chamber (15 m3) equiped with a single mode stirrer and two TEM horns set in cross-polarization in order to enhance the unpolarized character of the stochastic fields. Frequencies of interest are between 900 MHz and 2,5 GHz. The set of results points out that what could be firstly seen as a drawback - the cubic shape - can be effectively overcome by the design quality of the stirrer. Space homogeneity, quality factor, chamber gain, stirring ratio and CDF at 900MHz and 1800MHz (GSM, DECT and DCS mobile radio systems) are presented and critically commented.
UR - http://www.scopus.com/inward/record.url?scp=35348923589&partnerID=8YFLogxK
U2 - 10.1109/CEEM.2006.257991
DO - 10.1109/CEEM.2006.257991
M3 - Conference contribution
AN - SCOPUS:35348923589
SN - 1424401836
SN - 9781424401833
T3 - Proceedings - Fourth Asia-Pacific Conference on Environmental Electromagnetics, CEEM'2006
SP - 449
BT - Proceedings - Fourth Asia-Pacific Conference on Environmental Electromagnetics, CEEM'2006
T2 - 4th Asia-Pacific Conference on Environmental Electromagnetics, CEEM'2006
Y2 - 1 August 2006 through 4 August 2006
ER -