Résumé
Optimisation of the confinement and sustainability of a thermonuclear plasma requires methods to monitor processes in the plasma. In this work three materials were used as activation targets (Ti, MgF2 and a TiVAl compound). They were placed inside the joint European Torus (JET) vacuum chamber. Certain gamma-ray emitting radionuclides (7Be, 54Mn, 56Co, 57Co, 58Co and 46Sc) were measured using ultra low-level gamma-ray spectrometry in an underground laboratory 1-2 months after activation. They were found to arise from neutron activation of bulk sample material and surface contaminants sputtered from other Tokamak parts. Decision thresholds for some activation products were determined in order to aid in giving upper bounds for the flux of charged particles.
| langue originale | Anglais |
|---|---|
| Pages (de - à) | 1130-1135 |
| Nombre de pages | 6 |
| journal | Applied Radiation and Isotopes |
| Volume | 64 |
| Numéro de publication | 10-11 |
| Les DOIs | |
| état | Publié - oct. 2006 |
Empreinte digitale
Examiner les sujets de recherche de « A low-level activation technique for monitoring thermonuclear fusion plasma conditions ». Ensemble, ils forment une empreinte digitale unique.Contient cette citation
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver