Thermal analysis of an exposed tungsten edge in the JET divertor

G. Arnoux, J. Coenen, B. Bazylev, Y. Corre, G. F. Matthews, I. Balboa, M. Clever, R. Dejarnac, S. Devaux, T. Eich, E. Gauthier, L. Frassinetti, J. Horacek, S. Jachmich, D. Kinna, S. Marsen, Ph Mertens, R. A. Pitts, M. Rack, G. SergienkoB. Sieglin, M. Stamp, V. Thompson

Research output: Contribution to journalArticlepeer-review

Abstract

Abstract In the recent melt experiments with the JET tungsten divertor, we observe that the heat flux impacting on a leading edge is 3-10 times lower than a geometrical projection would predict. The surface temperature, tungsten vaporisation rate and melt motion measured during these experiments is consistent with the simulations using the MEMOS code, only if one applies the heat flux reduction. This unexpected observation is the result of our efforts to demonstrate that the tungsten lamella was melted by ELM induced transient heat loads only. This paper describes in details the measurements and data analysis method that led us to this strong conclusion. The reason for the reduced heat flux are yet to be clearly established and we provide some ideas to explore. Explaining the physics of this heat flux reduction would allow to understand whether it can be extrapolated to ITER.

Original languageEnglish
Article number48599
Pages (from-to)415-419
Number of pages5
JournalJournal of Nuclear Materials
Volume463
DOIs
Publication statusPublished - 22 Jul 2015

Fingerprint

Dive into the research topics of 'Thermal analysis of an exposed tungsten edge in the JET divertor'. Together they form a unique fingerprint.