Tests of load resilient matching procedure for the ITER ICRH system on a mock-up and layout proposal

P. Dumortier, P. Lamalle, N. Leroy, A. Messiaen, M. Vervier

Research output: Contribution to journalArticlepeer-review

Abstract

An external matching option of the ITER ICRH system has been successfully tested by means of a mock-up of the antenna plug loaded by a movable water load. The problem of coupling between the straps of the antenna array is solved by the use of decouplers and passive power distribution. High load resilience is obtained for different toroidal phasings needed for heating or current drive. A straightforward matching procedure for which the decouplers and half of the matching parameters are pre-adjusted in vacuum condition has been developed.

Original languageEnglish
Pages (from-to)758-764
Number of pages7
JournalFusion Engineering and Design
Volume82
Issue number5-14
DOIs
Publication statusPublished - Oct 2007

Keywords

  • Conjugate-T
  • External matching
  • ICRF
  • ICRH
  • ITER
  • Load resilience

Fingerprint

Dive into the research topics of 'Tests of load resilient matching procedure for the ITER ICRH system on a mock-up and layout proposal'. Together they form a unique fingerprint.