Abstract
By the use of a mock-up operated at higher frequency it is possible to measure with good accuracy the rf characteristics of an ICRH antenna, the plasma loading being simulated by a water tank in front of it. This concept has motivated the construction of the mock-up of the antenna array foreseen for ITER.
| Original language | English |
|---|---|
| Pages (from-to) | 367-375 |
| Number of pages | 9 |
| Journal | Fusion Engineering and Design |
| Volume | 74 |
| Issue number | 1-4 |
| DOIs | |
| Publication status | Published - Nov 2005 |
Keywords
- Antenna array
- ICRH
- ITER
- Mock-up
- Water rf load