Abstract
By the use of a mock-up operated at higher frequency it is possible to measure with good accuracy the rf characteristics of an ICRH antenna, the plasma loading being simulated by a water tank in front of it. This concept has motivated the construction of the mock-up of the antenna array foreseen for ITER.
Original language | English |
---|---|
Pages (from-to) | 367-375 |
Number of pages | 9 |
Journal | Fusion Engineering and Design |
Volume | 74 |
Issue number | 1-4 |
DOIs | |
Publication status | Published - Nov 2005 |
Keywords
- Antenna array
- ICRH
- ITER
- Mock-up
- Water rf load