Complete space - Time validation of a single mode stirrer reverberation chamber for immunity testing

Marc Piette

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

This paper gives an overview of the validation measurements in a small cubic reverberation chamber (15 m3) equiped with a single mode stirrer and two TEM horns set in cross-polarization in order to enhance the unpolarized character of the stochastic fields. Frequencies of interest are between 900 MHz and 2,5 GHz. The set of results points out that what could be firstly seen as a drawback - the cubic shape - can be effectively overcome by the design quality of the stirrer. Space homogeneity, quality factor, chamber gain, stirring ratio and CDF at 900MHz and 1800MHz (GSM, DECT and DCS mobile radio systems) are presented and critically commented.

Original languageEnglish
Title of host publicationProceedings - Fourth Asia-Pacific Conference on Environmental Electromagnetics, CEEM'2006
Pages449
Number of pages1
DOIs
Publication statusPublished - 2006
Event4th Asia-Pacific Conference on Environmental Electromagnetics, CEEM'2006 - Dalian, China
Duration: 1 Aug 20064 Aug 2006

Publication series

NameProceedings - Fourth Asia-Pacific Conference on Environmental Electromagnetics, CEEM'2006

Conference

Conference4th Asia-Pacific Conference on Environmental Electromagnetics, CEEM'2006
Country/TerritoryChina
CityDalian
Period1/08/064/08/06

Fingerprint

Dive into the research topics of 'Complete space - Time validation of a single mode stirrer reverberation chamber for immunity testing'. Together they form a unique fingerprint.