Timing and source of the maximum of the transthoracic impedance cardiogram (dZ/dt) in relation to the H-I-J complex of the longitudinal ballistocardiogram under gravity and microgravity conditions

E. Luchitskaya, Q. Deliere, A. Diedrich, N. Pattyn, A. Almorad, L. Beck, P. Gauger, U. Limper, I. Funtova, R. M. Baevsky, P. F. Migeotte, J. Tank

Publikation: Beitrag in Buch/Bericht/KonferenzbandKonferenzbeitragBegutachtung

Abstract

The transthoracic impedance cardiogram (ICG) and the acceleration ballistocardiogram (BCG) measured close to the center of mass of the human body are generated by changes of blood distribution. The transthoracic ICG is an integrated signal covering the whole thorax and spatial resolution is poor. Comparison between both signals can be used to elucidate the source of the ICG signal. We recorded the ECG, ICG, and BCG simultaneously in healthy subjects under resting and microgravity conditions during parabolic flights. The time interval between the R-peak of the ECG and the maximum of the ICG (R-dZ/dtmax) and the time interval between the R-peak of the ECG and the I-peak in the BCG (R-I) differed significantly (p<0.0001). The I-peak in the BCG always occurred earlier during systole than dZ/dtmax. The delay of dZ/dtmax ranged between 23 and 28 ms at rest and was lowest under microgravity conditions (12±4 ms, p<0.02). Our results suggest that both signals have different sources. Combination of modern imaging techniques with classical non invasive approaches to detect changes of blood distribution may provide new insights into the complex interaction between blood flow and mechanocardiographic signals like the BCG.

OriginalspracheEnglisch
Titel2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013
Herausgeber (Verlag)Institute of Electrical and Electronics Engineers Inc.
Seiten7294-7297
Seitenumfang4
ISBN (Print)9781457702167
DOIs
PublikationsstatusVeröffentlicht - 2013
Veranstaltung2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013 - Osaka, Japan
Dauer: 3 Juli 20137 Juli 2013

Publikationsreihe

NameProceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
ISSN (Print)1557-170X

Konferenz

Konferenz2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013
Land/GebietJapan
OrtOsaka
Zeitraum3/07/137/07/13

Fingerprint

Untersuchen Sie die Forschungsthemen von „Timing and source of the maximum of the transthoracic impedance cardiogram (dZ/dt) in relation to the H-I-J complex of the longitudinal ballistocardiogram under gravity and microgravity conditions“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren