Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

The source of and a simple way to avoid ground loops in biasing Langmuir probe array

  • I. Shesterikov
  • , K. Crombe
  • , R. Ochoukov
  • , A. Kostic
  • , M. Usoltceva
  • , J. M. Noterdaeme
  • Max-Planck-Institut für Plasmaphysik
  • University of Ghent

Publikation: Beitrag in FachzeitschriftArtikelBegutachtung

1 Zitat (Scopus)

Abstract

Biasing multiple Langmuir probes arranged in an array through one voltage source presents a more compact, reliable and convenient way to bias than using an individual source for each probe. This approach however is the subject of ground loops and several methods have been discussed to avoid them. The high frequency isolation transformer is considered to be a best way to break ground loops since it does not require an additional power supplies and, in general, any other electric circuit. The presented results demonstrate a considerable suppression of the ground loop noise using this technique. The following limitations should be considered in this approach: only an AC voltage bias should be applied, the relatively high internal resistance of the transformer should be taken into account, the frequency of the AC bias signal should correspond to the transforner bandwidth.

OriginalspracheEnglisch
AufsatznummerP01002
FachzeitschriftJournal of Instrumentation
Jahrgang14
Ausgabenummer1
DOIs
PublikationsstatusVeröffentlicht - 3 Jan. 2019

Fingerprint

Untersuchen Sie die Forschungsthemen von „The source of and a simple way to avoid ground loops in biasing Langmuir probe array“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren