Complete space - Time validation of a single mode stirrer reverberation chamber for immunity testing

Marc Piette

Publikation: Beitrag in Buch/Bericht/KonferenzbandKonferenzbeitragBegutachtung

Abstract

This paper gives an overview of the validation measurements in a small cubic reverberation chamber (15 m3) equiped with a single mode stirrer and two TEM horns set in cross-polarization in order to enhance the unpolarized character of the stochastic fields. Frequencies of interest are between 900 MHz and 2,5 GHz. The set of results points out that what could be firstly seen as a drawback - the cubic shape - can be effectively overcome by the design quality of the stirrer. Space homogeneity, quality factor, chamber gain, stirring ratio and CDF at 900MHz and 1800MHz (GSM, DECT and DCS mobile radio systems) are presented and critically commented.

OriginalspracheEnglisch
TitelProceedings - Fourth Asia-Pacific Conference on Environmental Electromagnetics, CEEM'2006
Seiten449
Seitenumfang1
DOIs
PublikationsstatusVeröffentlicht - 2006
Veranstaltung4th Asia-Pacific Conference on Environmental Electromagnetics, CEEM'2006 - Dalian, China
Dauer: 1 Aug. 20064 Aug. 2006

Publikationsreihe

NameProceedings - Fourth Asia-Pacific Conference on Environmental Electromagnetics, CEEM'2006

Konferenz

Konferenz4th Asia-Pacific Conference on Environmental Electromagnetics, CEEM'2006
Land/GebietChina
OrtDalian
Zeitraum1/08/064/08/06

Fingerprint

Untersuchen Sie die Forschungsthemen von „Complete space - Time validation of a single mode stirrer reverberation chamber for immunity testing“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren